Error message

  • Notice: Undefined offset: 223 in user_node_load() (line 3697 of /home/tcipgpro/public_html/modules/user/user.module).
  • Notice: Trying to get property 'name' of non-object in user_node_load() (line 3697 of /home/tcipgpro/public_html/modules/user/user.module).
  • Notice: Undefined offset: 223 in user_node_load() (line 3698 of /home/tcipgpro/public_html/modules/user/user.module).
  • Notice: Trying to get property 'picture' of non-object in user_node_load() (line 3698 of /home/tcipgpro/public_html/modules/user/user.module).
  • Notice: Undefined offset: 223 in user_node_load() (line 3699 of /home/tcipgpro/public_html/modules/user/user.module).
  • Notice: Trying to get property 'data' of non-object in user_node_load() (line 3699 of /home/tcipgpro/public_html/modules/user/user.module).

Networked Loads in the Distribution Grid

Wang, Z., Li, X., Muthukumar, V., Scaglione, A., Peisert, S., McParland, C.
Citation:

Asia-Pacific Signal & Information Processing Association Annual Summit and Conference (APSIPA ASC), pp.1,7, 3-6 Dec. 2012.

Visit Publisher Online Entry:
Abstract:

Central utility services are increasingly networked systems that use an interconnection of sensors and programmable logic controllers, and feed data to servers and human-machine interfaces. These systems are connected to the Internet so that they can be accessed remotely, and the network in these plants is structured according to the SCADA model. Although the physical systems themselves are generally designed with high degrees of safety in mind, and designers of computer systems are well advised to incorporate computer security principles, a combined framework for supervisory control of the physical and cyber architectures in these systems is still lacking. Often absent are provisions to defend against external and internal attacks, and even operator errors that might bypass currently standalone security measures to cause undesirable consequences. In this paper we examine a prototypical instance of SCADA network in the distribution network that handles central cooling and heating for a set of buildings. The electrical loads are networked through programmable logic controllers (PLCs), electrical meters, and networks that deliver data to and from servers that are part of a SCADA system, which has grown in size and complexity over many years.

Publication Status:
Published
Publication Type:
Proceedings
Publication Date:
12/03/2012
Copyright Notice:

This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.

  1. The following copyright notice applies to all of the above items that appear in IEEE publications: "Personal use of this material is permitted. However, permission to reprint/publish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from IEEE."

  2. The following copyright notice applies to all of the above items that appear in ACM publications: "© ACM, effective the year of publication shown in the bibliographic information. This file is the author’s version of the work. It is posted here by permission of ACM for your personal use. Not for redistribution. The definitive version was published in the journal or proceedings indicated in the bibliographic data for each item."

  3. The following copyright notice applies to all of the above items that appear in IFAC publications: "Document is being reproduced under permission of the Copyright Holder. Use or reproduction of the Document is for informational or personal use only."